How does actual steam capacity of a steam generator change in response to higher operating pressure?
When the operating pressure of a steam generator (similarly to any other steam boiler) changes, properties of the saturated steam also change - specific volume reduces while steam density and specific enthalpy grow. Hence, with operating pressure growing, net steam output falls. The total energy components remains unchanged. At your request, AMELIN engineers will estimate the optimal steam generator capacity for your needs and send you a technical and commercial proposal.